Product Information

Simplified operation, minimum maintenance and long, economical service are a few of the advantages you get with an ARR-M Series 3 phase utility charger.

Electrical and mechanical design features make it ideal for a wide variety of utility, industrial and other standby power supply applications.

unipower-gold-seal
FIVE YEAR WARRANTY
Features and Options
  • Microprocessor Controlled
  • Digital Metering
  • Simultaneous Voltage & Current Readings
  • 24, 48, 125 & 250V Output
  • 25A to 500A
  • Listed to UL/CSA
  • CE safety and EMC standards tested and compliant
  • Designed to NEMA PE5 standard insures reliable performance under real world conditions
  • Low Maintenance
  • Common control board for all output voltages and current ratings reduce spares requirements and simplifies maintenance.
  • Remote Communications - MODBUS & DNP3
  • User definable control and alarm set points
  • Temperature Compensation
  • High efficiency & power factor
  • Design provides for reliable power requirements on or off the battery

GENERAL SPECIFICATIONS

Input and Output Ratings
Standard Inputs: 208, 240, 480VAC, three phase, 60Hz, 6-Pulse, Filtered output
575, 600VAC, and other 3-Phase Input Voltages available, also 50Hz models available – consult the factory
12-Pulse models available for 60Hz and 50Hz- please consult the factory
Output Voltages: 24, 48, 125, 250 VDC
Output Currents: 25A – 500A (up to 1000A available - consult the factory)

Standard Control Modules
All three-phase ARR-M chargers, regardless of output voltage & current utilize the same control. This feature allows for minimum parts inventory and simplifies maintenance.

Regulation
DC float voltage is maintained within ± 0.5 percent from no load to full load with input frequency variations of ±5 percent and with AC input voltage variation of +10%/-12% of the nominal input voltage.
During operation the maximum output transient does not exceed 6% of the initial steady-state voltage for sudden load changes between 10% and 90% of rated output. Recovery takes less than 300mS.

Current Limiting
The current limiting circuit is factory set at 100% and is adjustable from 20% up to 100% of rated output.
It will hold down to short circuit.

Power Factor
The typical power factor is 0.88 when tested on a resistive load and batteries.

Electrical noise – Filtered Output
Nominal ripple when connected to a battery rated four times the charger output current rating:
• 24V & 48V Models – 30mV or less (32dBrnc) (15mV available with extra filtering)
• 125V Models – 100mV (30mV available with extra filtering)
• 250V Models – 200mV (150mV available with extra filtering)

Off-battery Operation
The ARR-M product series can be operated on a principally resistive load with the battery disconnected for maintenance purposes.

Circuit Protection
Selection of input AC circuit breakers to suite input voltage and capacity as specified by client.
10kAIC and higher capacity rating of output DC circuit breakers available.
Also, a single pole DC fuse is provided in the positive leg of the DC output.
Surge suppression on input and output for protection of the transient voltages.
Optional lightning arrestor available for over-voltage transients caused by external lightning.
Reverse polarity.

Ambient Operating Conditions
The ARR-M series chargers will operate at 110% of rated DC output, continuously in ambient temperatures of 32°F to 122°F (0°C to 50°C) up to an altitude of 3,300 ft. (1,000m). De-rating of 3.6°F (2°C) for every 990 ft. (300m) over 3,300 ft. above sea level.
These units can be safely stored for up to one year at temperatures ranging from -40°F to 185°F (-40°C to 85°C).

Humidity
The ARR-M series chargers will continue to operate in humidity levels of 0-95% (non-condensing).

Audible noise
45-65dBa at 3 ft. (1m) from any vertical surface of the charger.

Mechanical Features
• Enclosure – NEMA-1 (IP20), steel with hinged front panel door
• Finish – Baked powder coat; ANSI-61 Gray
• Cooling – Natural convection cooling up to 100A output current; forced air assisted cooling for units above 100A output current
• Door opens approximately 90 degrees for easy access to interior
• Control board mounted on backside of door for easy access
• Serviceable components are accessible and removable from the front
• Knockouts for cables are provided
• Cabinets are floor mounted and provide a 3 inch clearance at the bottom to facilitate handling by a lift truck or pallet truck
• Two half turn screw terminals are provided for standard door fastening

Design Features
• UL/ANSI 1012 (LISTED)
• NEMA PE5 complaint
• CSA C22.2 107.1 certified and applicable IEC standard compliant
• 30 year design life
• MTBF – 300,000 hours
• MTTR – less than one hour

Standard Features
• Microprocessor controlled
• Digital Display: 2 line by 20 characters; simultaneous display of voltage and current with 0.5% accuracy
• High Voltage Shutdown
• Common charger fail (two sets of form-c contacts)
• Float and Equalize settings are via keypad
• Individual current limit setting for Float and Equalize
• Front Panel Indicators - Charger fail LED: Red (flashing) - AC on LED: Green
• Event Log: last 150 charger events
• Equalize Timer – 1 to 4095 Hours (one hour increments)
• Periodic Equalize – 1 to 4095 Days (one day increments)
• Consult the factory for Hi Capacity Breakers.
• Charge Modes - Float (Manual & Automatic) - Equalize (Manual & Automatic) - Anti-depressant (Ni-cad batteries) - Formation (battery restoration)

Standard Alarm Package
• Rectifier Fail
• Battery High DC Voltage
• Battery Low DC Voltage
• Charger High DC Volts
• Charger Low DC Volts
• Ground Fault (POS)
• Ground Fault (NEG)
• AC Fail
• Charger Fail (Summary)
• Rectifier Fail - triggered by low DC current (2% of rated output), AC Fail, and decaying DC voltage Alarms provide independently adjusted settings for alarm level and time delay

ADDITIONAL ALARM FEATURES
• 2nd Level Battery High DC Voltage
• 2nd Level Battery Low DC Voltage
- End of Discharge Alarm
• Rectifier High Current Alarm
• Equalize Alarm
• Charger Over-temperature Alarm

24VDC OUTPUT BASE MODELS *
Model Input
Voltage
Input
Current
Output
Current
Dimension
H x W x D
inches (mm)
Weight
ARR-M02425F 208V
240V
480V
3.1A
2.7A
1.4A
25A 30 x 21 x 15 (762 x 533 x 381) 143lb | 65kg
ARR-M02430F 208V
240V
480V
3.7A
3.2A
1.6A
30A 30 x 21 x 15 (762 x 533 x 381) 150lb | 68kg
ARR-M02440F 208V
240V
480V
5.0A
4.3A
2.2A
40A 39 x 24 x 20 (991 x 610 x 508) 242lb | 110kg
ARR-M02450F 208V
240V
480V
6.2A
5.4A
2.7A
50A 39 x 24 x 20 (991 x 610 x 508) 287lb | 130kg
ARR-M02475F 208V
240V
480V
9.4A
8.1A
4.0A
75A 39 x 24 x 20 (991 x 610 x 508) 373lb | 169kg
ARR-M024100F 208V
240V
480V
12.5A
10.8A
5.4A
100A 51 x 24 x 20 (1295 x 610 x 508) 430lb | 195kg
ARR-M024125F 208V
240V
480V
15.6A
13.5A
6.8A
125A 60 x 36 x 25 (1524 x 914 x 635) 441lb | 200kg
ARR-M024150F 208V
240V
480V
18.7A
16.2A
8.1A
150A 60 x 36 x 25 (1524 x 914 x 635) 463lb | 210kg
ARR-M024200F 208V
240V
480V
24.9A
21.6A
10.8A
200A 60 x 36 x 25 (1524 x 914 x 635) 551lb | 250kg
ARR-M024250F 208V
240V
480V
31.2A
27.0A
13.5A
250A 60 x 36 x 25 (1524 x 914 x 635) 617lb | 280kg
ARR-M024300F 208V
240V
480V
37.4A
32.4A
16.2A
300A 60 x 36 x 25 (1524 x 914 x 635) 642lb | 291kg
ARR-M024400F ** 208V
240V
480V
49.9A
43.2A
21.6A
400A 60 x 36 x 25 (1524 x 914 x 635) 782lb | 355kg
ARR-M024500F ** 208V
240V
480V
62.4A
54.0A
27.0A
500A 60 x 36 x 25 (1524 x 914 x 635) 807lb | 366kg
* Models listed are 'base' models which require configuration to order. Only one input voltage may be specified per charger. ‘Multi-tap’ models are not available. Please consult sales.
** These models have an external transformer. See datasheet for details.

STANDARD 48VDC OUTPUT MODELS *
Model Input
Voltage
Input
Current
Output
Current
Dimension
H x W x D
inches (mm)
Weight
ARR-M04825F 208V
240V
480V
6.2A
5.4A
2.7A
25A 30 x 21 x 15 (762 x 533 x 381) 197lb | 89kg
ARR-M04830F 208V
240V
480V
7.5A
6.5A
3.2A
30A 39 x 24 x 20 (991 x 610 x 508) 288lb | 131kg
ARR-M04840F 208V
240V
480V
10.0A
8.6A
4.3A
40A 39 x 24 x 20 (991 x 610 x 508) 348lb | 158kg
ARR-M04850F 208V
240V
480V
12.5A
10.8A
5.4A
50A 39 x 24 x 20 (991 x 610 x 508) 380lb | 172kg
ARR-M04875F 208V
240V
480V
18.8A
16.2A
8.1A
75A 51 x 24 x 20 (1295 x 610 x 508) 438lb | 199kg
ARR-M048100F 208V
240V
480V
24.9A
21.6A
10.8A
100A 51 x 24 x 20 (1295 x 610 x 508) 501lb | 227kg
ARR-M048125F 208V
240V
480V
31.2A
27.0A
13.5A
125A 60 x 36 x 25 (1524 x 914 x 635) 517lb | 235kg
ARR-M048150F 208V
240V
480V
37.4A
32.4A
16.2A
150A 60 x 36 x 25 (1524 x 914 x 635) 517lb | 235kg
ARR-M048200F 208V
240V
480V
49.9A
43.2A
21.6A
200A 60 x 36 x 25 (1524 x 914 x 635) 697lb | 316kg
ARR-M048250F 208V
240V
480V
62.4A
54.0A
27.0A
250A 60 x 36 x 25 (1524 x 914 x 635) 747lb | 339kg
ARR-M048300F 208V
240V
480V
74.8A
64.8A
32.4A
300A 60 x 36 x 25 (1524 x 914 x 635) 772lb | 350kg
ARR-M048400F ** 208V
240V
480V
99.8A
86.5A
43.2A
400A 60 x 36 x 25 (1524 x 914 x 635) 865lb | 392kg
ARR-M048500F ** 208V
240V
480V
124.7A
108.1A
54.0A
500A 60 x 36 x 25 (1524 x 914 x 635) 1097lb | 498kg
* Models listed are 'base' models which require configuration to order. Only one input voltage may be specified per charger. ‘Multi-tap’ models are not available. Please consult sales.
** These models have an external transformer. See datasheet for details.

125VDC OUTPUT BASE MODELS *
Model Input
Voltage
Input
Current
Output
Current
Dimension
H x W x D
inches (mm)
Weight
ARR-M12525F 208V
240V
480V
15.6A
13.5A
6.8A
25A 39 x 24 x 20 (991 x 610 x 508) 366lb | 166kg
ARR-M12530F 208V
240V
480V
18.7A
16.2A
8.1A
30A 39 x 24 x 20 (991 x 610 x 508) 388lb | 176kg
ARR-M12540F 208V
240V
480V
24.9A
21.6A
10.8A
40A 39 x 24 x 20 (991 x 610 x 508) 426lb | 193kg
ARR-M12550F 208V
240V
480V
31.2A
27.0A
13.5A
50A 39 x 24 x 20 (991 x 610 x 508) 467lb | 212kg
ARR-M12575F 208V
240V
480V
46.8A
40.5A
20.3A
75A 51 x 24 x 20 (1295 x 610 x 508) 622lb | 282kg
ARR-M125100F 208V
240V
480V
62.4A
54.0A
27.0A
100A 51 x 24 x 20 (1295 x 610 x 508) 647lb | 294kg
ARR-M125125F 208V
240V
480V
77.9A
67.6A
33.8A
125A 60 x 36 x 25 (1524 x 914 x 635) 730lb | 331kg
ARR-M125150F 208V
240V
480V
93.5A
81.1A
40.5A
150A 60 x 36 x 25 (1524 x 914 x 635) 780lb | 354kg
ARR-M125200F 208V
240V
480V
124.7A
108.1A
54.0A
200A 60 x 36 x 25 (1524 x 914 x 635) 1037lb | 470kg
ARR-M125250F ** 208V
240V
480V
155.9A
135.1A
67.6A
250A 60 x 36 x 25 (1524 x 914 x 635) 1037lb | 470kg
ARR-M125300F ** 208V
240V
480V
187.1A
162.1A
81.1A
300A 60 x 36 x 25 (1524 x 914 x 635) 1415lb | 642kg
ARR-M125400F ** 208V
240V
480V
249.4A
216.2A
108.1A
400A 60 x 36 x 25 (1524 x 914 x 635) 1425lb | 646kg
ARR-M125500F ** 208V
240V
480V
311.8A
270.2A
135.1A
500A 60 x 36 x 25 (1524 x 914 x 635) 1703lb | 773kg
* Models listed are 'base' models which require configuration to order. Only one input voltage may be specified per charger. ‘Multi-tap’ models are not available. Please consult sales.
** These models have an external transformer. See datasheet for details.

250VDC OUTPUT BASE MODELS *
Model Input
Voltage
Input
Current
Output
Current
Dimension
H x W x D
inches (mm)
Weight
ARR-M25025F 208V
240V
480V
31.2A
27.0A
13.5A
25A 39 x 24 x 20 (991 x 610 x 508) 442lb | 201kg
ARR-M25030F 208V
240V
480V
37.4A
32.4A
16.2A
30A 51 x 24 x 20 (1295 x 610 x 508) 597lb | 271kg
ARR-M25040F 208V
240V
480V
49.9A
43.2A
21.6A
40A 51 x 24 x 20 (1295 x 610 x 508) 597lb | 271kg
ARR-M25050F 208V
240V
480V
62.4A
54.0A
27.0A
50A 51 x 24 x 20 (1295 x 610 x 508) 622lb | 282kg
ARR-M25075F 208V
240V
480V
93.6A
81.1A
40.5A
75A 60 x 36 x 25 (1524 x 914 x 635) 755lb | 343kg
ARR-M250100F 208V
240V
480V
124.7A
108.1A
54.0A
100A 60 x 36 x 25 (1524 x 914 x 635) 987lb | 448kg
ARR-M250125F 208V
240V
480V
155.9A
135.1A
67.6A
125A 60 x 36 x 25 (1524 x 914 x 635) 987lb | 448kg
ARR-M250150F 208V
240V
480V
187.1A
162.1A
81.1A
150A 60 x 36 x 25 (1524 x 914 x 635) 1340lb | 608kg
ARR-M250200F ** 208V
240V
480V
249.4A
216.2A
108.1A
200A 60 x 36 x 25 (1524 x 914 x 635) 1400lb | 635kg
ARR-M250250F ** 208V
240V
480V
311.8A
270.2A
135.1A
250A 60 x 36 x 25 (1524 x 914 x 635) 1653lb | 750kg
ARR-M250300F ** 208V
240V
480V
374.1A
324.2A
162.1A
300A 60 x 36 x 25 (1524 x 914 x 635) 1985lb | 900kg
ARR-M250400F ** 208V
240V
480V
498.8A
432.3A
216.2A
400A 60 x 36 x 25 (1524 x 914 x 635) 1985lb | 900kg
ARR-M250500F ** 208V
240V
480V
623.6A
540.4A
270.2A
500A 60 x 36 x 25 (1524 x 914 x 635) 2410lb | 1093kg
* Models listed are 'base' models which require configuration to order. Only one input voltage may be specified per charger. ‘Multi-tap’ models are not available. Please consult sales.
** These models have an external transformer. See datasheet for details.