Scimitar 1000 & 2000


Product Information
The SCIMITAR Series are 1kVA and 2kVA inverters which are 19” rack-mountable and only 1RU high. They operate from a 12V, 24V or 48VDC source and produce a 115 or 230VAC output.
The tightly regulated low distortion 50 or 60Hz sine wave is produced by DSP controlled power circuits using an advanced high frequency, pulsewidth modulation technique which achieves up to 92% efficiency.
A built-in Static Transfer Switch allows connection of a utility or other AC power source which can be switched to the load automatically in the event that the inverter switches off.
In normal operation these inverters isolate the load from wide voltage swings , transients and noise usually present in the AC utility and which can cause equipment reliability problems.
Output voltage and frequency are programmable from the front panel, as well as Baud Rate for the RS232 communications interface which can be used for remote monitoring.
Two Year warranty
Features and Options
- 19-Inch x 1UR Rack Mounting
- 1000 or 2000 VA Output Capacity
- 115VAC or 230VAC Output
- 50 or 60Hz Low Distortion Sine Wave
- 12, 24 or 48VDC Input
- -20 to +60C Operating Temperature Range
- Static Transfer Switch Built-in
- Programmable Output Voltage and Frequency (Front panel DIP switch)
- Powers Reactive Loads
- LED Status Display
- Relay Alarm Output
SPECIFICATIONS
|
||
---|---|---|
INPUT | ||
Voltage | 12VDC (10-16VDC) 24VDC (20-32VDC) 48VDC (42-62VDC) |
|
Current (max.) | 1kVA Models 98.8A @ 12V 48.5A @ 24V 22.8A @ 48V |
2kVA Models 186.1A @ 12V 95.6A @ 24V 45.0A @ 48V |
OUTPUT | ||
Voltage | 100/110/115/120VAC ±3% (switch selectable) 200/220/230/240VAC ±3% (switch selectable) |
|
Power | See model table opposite | |
Frequency | 50Hz or 60Hz ±0.05% (switch selectable) | |
Efficiency | 86-92% depending on model | |
Peak Output Current | 1kVA Models 15A @ 120VAC 9A @ 230VAC |
2kVA Models 25A @ 120VAC 11A @ 230VAC |
Output Waveform | Pure Sine Wave <3% THD (R Load) | |
TRANSFER FUNCTION (-STS OPTION) | ||
AC Input Range | 90 – 130VAC (110VAC nominal) 180-260VAC (230VAC nominal) |
|
Frequency | 47-63Hz | |
Transfer Time | 4-6mS | |
Alarm Relay | Form-C dry contacts, indicates presence of AC Utility supply | |
OTHER TECHNICAL DATA | ||
Protection | Output Overload; Output Short Circuit; Input Reverse Polarity (fuse); Input Undervoltage; Input Overvoltage; Over Temperature | |
Alarms | General alarm signal activated by an open photo-relay if in fault mode, available at rear signal connector | |
Display | OVP – UVP – OTP – OLP – VAC – AMP – WATT – VDC – TEMP – Hz | |
Control Port | RS232C – Baud Rates – 2400, 4800, 9600, 19200 (switch selectable) | |
SNMP (Option) | Operates in conjunction with NetAgent UPS SNMP Agent | |
Temperature Range | Operating: -20°C to +60°C Storage: -30°C to +70°C |
|
MTBF | > 98,000 hrs @ 25°C ambient, nominal output voltage & full load | |
DESIGN STANDARDS | ||
Safety | 120VAC Models: UL60950-1 (Listed – E130645) 230VAC Models: EN60950-1 |
|
EMC | 120VAC Models: FCC Class B 230VAC Models: EN 55022:1998/ A1:2000/A2:2003(Class B) | EN 55024: 1998/ A1:2001/A2:2003 | EN 61000-3-2:2000/A2: 2005 | EN 61000-3-3:1995/A1: 2001 | IEC 61000-4-2:1995/ A1:1998/A2:2000 | IEC 61000-4-3:2002/A1:2002 | IEC 61000-4-4:2004 | IEC 61000-4-5:1995/A1:2000 | IEC 61000-4-6:1996/A1:2001 | IEC 61000-4-8:1993/A1:2000 | IEC 61000-4-11:2004 |
|
MECHANICAL | ||
Dimensions, inches (mm) | 19 (484) W x 1.73 (44.0) H x 16.1 (408.7) D | |
Weight | 19.8lbs / 9Kg | |
Mounting | 19″ Rack, 1RU |
STANDARD MODELS | |||||
---|---|---|---|---|---|
Model Number |
Output Power 4 |
Output Voltage 1, 2, 3 |
Input Voltage |
SNMP 6 | |
INV1210R-N 5 | 1kVA @ 0.85PF 850W @ 1.0PF |
115VAC | 12VDC | Option | |
INV2410R-N 5 | 24VDC | Option | |||
INV4810R-N 5 | 48VDC | Option | |||
INV1210RH-E | 230VAC | 12VDC | Option | ||
INV2410RH-E | 24VDC | Option | |||
INV4810RH-E | 48VDC | Option | |||
INV1220R-N 5 | 2kVA @ 0.85PF 1600W @ 1.0PF |
115VAC | 12VDC | Option | |
INV2420R-N 5 | 2kVA @ 0.85PF 1700W @ 1.0PF |
24VDC | Option | ||
INV4820R-N 5 | 48VDC | Option | |||
INV1220RH-E | 2kVA @ 0.80 PF 1600W @ 1 PF |
230VAC | 12VDC | Option | |
INV2420RH-E | 2kVA @ 0.85 PF 1700W @ 1 PF |
24VDC | Option | ||
INV4820RH-E | 48VDC | Option | |||
Notes:
|