The SAGEON Micro 200 amp DC power system delivers the unmatched capability of a full size SAGEON Power System in a compact and cost effective solution.
Designed to deliver up to 200 amps of power for 24 volt or 48 volt systems, the Micro Power Module provides the flexibility to put power where it is needed. The Micro Power Module also offers the flexibility to configure the best solution for your needs with options including integrated battery disconnects and load distribution; all in space saving configurations from two through seven rack units.
The SAGEON Micro 200 amp DC power system consists of a power frame that includes the SAGEON Controller, mechanical mounting for up to seven SAGEON Micro Rectifiers, all inter-system cabling, and optional items including AC input breakers, battery disconnects, DC distribution breakers and fuses, and remote communications – all factory installed and tested. Installation cost and time are minimized because there is only one component to install. To complete your system simply connect your AC and DC cables, plug-in the SAGEON Micro Rectifiers, and you are ready to go.
In addition to the basic control functions, the SAGEON Micro 200 amp DC power system supports all of the advanced functionality available in a SAGEON Power System including; remote monitor and control, battery testing, individual cell monitoring, programmable battery recharge current, and site monitoring.
Three Year warranty
Features and Options
- High Power Density
- 200A Capacity
- 24VDC or 48VDC
- 2400W Hot-Swap Rectifiers
- Battery Testing
- Battery Monitoring
- Remote Monitoring & Control
- Programmable Battery Recharge
- Field Replaceable Controller
- LCD Display/Touchpad
SPECIFICATIONS
|
|
---|---|
INPUT | |
Voltage Range | AC 85-300VAC (L-N. 1ph, or 3ph-Y, 3ph-delta [option]. Fully protected up to 440VAC (L-N) |
Frequency | 47-63Hz |
Inrush Current | <9A RMS per rectifier |
THD | Line Harmonics meet EN61000-3-2 |
Power Factor | >0.98 for >50% output power |
OUTPUT | |
Voltage Range | -48VDC systems, adjustable range 42.0V to 59.5V +24VDC systems, adjustable range 21.0V to 30.0V |
Current Limit | Adjustable from 20 % to 120 % of rated output current |
Power Limit | Varies by rectifier model. See the rectifier brochures for more information. |
Efficiency | >90% at 100% output power for 48VDC systems >88% at 100% output power for 24V systems |
Regulation | ±1% or better over line, load and temperature |
Noise | .1% pk-pk max. |
Line Regulation | <1mV RMS Psophometrically weighted <32dBrnC Voiceband <10mV RMS and <100mV peak-to-peak (10kHz-100MHz) |
PROTECTION | |
Short Circuit | Can sustain short circuit at output terminals indefinitely |
Reverse Battery Polarity | Internal fuse at output of RECTIFIER, integral battery circuit breakers and detection/disconnection circuitry |
High Voltage Shutdown | Rectifier shuts down if output exceeds programmed overvoltage limit |
Electrostatic Discharge (ESD) | IEC 61000-4-2 (Level 4: Air 15kV, Contact 8kV) |
AC Surge | IEC 61000-4-4 (EFT), Level 4 IEC 61000-4-5 (Impulse), Level X: 6kV/3kA IEC 61000-4-12 (Ringwave), Level X: 6kV/500A |
RF Immunity | IEC 61000-4-3 (Radiated), Level 4 IEC 61000-4-6 (Conducted), Level 3 |
RF Emissions | CISPR 22 Class B, (Conducted & Radiated) |
ENVIRONMENTAL | |
Operating Temp. Range | -40°C to +55°C (Full Load) |
Derating Operation | 50% power at +70°C |
Storage Temp. Range | -40°C to +70°C |
Humidity | 0 to 100% relative humidity, condensing |
Acoustic Noise | <60dB (A weighting) |
PHYSICAL SPECIFICATIONS | |
Dimensions, inches (mm) | 3.4-13.6 (88-352) H x 19.0 (483) W x 14.0 (355) D – see configurations table |
Weight | 14-64lb (6-29kg) – see configurations table |
COMPLIANCE | |
EMC | ETSI EN 300 386 V1.3.2 (2002-12) |
Safety | IEC 60950, UL/CSA 60950 |
Environmental | ETSI EN 300 019 |
STANDARD SYSTEM CONFIGURATIONS | ||||
---|---|---|---|---|
Output Current |
Example | Height | Weight | |
40A | ![]() |
1RU | 14lb | 6kg | |
80A | ![]() |
2RU | 20lb | 9kg | |
120A | ![]() |
3RU | 29lb | 13kg | |
160A | ![]() |
4RU | 37lb | 17kg | |
200A | ![]() |
5RU | 46lb | 21kg | |
200A | ![]() |
6RU | 55lb | 25kg | |
200A | ![]() |
7RU | 64lb | 29kg |