Sageon III

Sageon III
Sageon
System Datasheet
System Manual
Base System Manual
SageView Software Manual
SageView Win 8/8.1 USB Driver Manual
48V Rectifier Datasheet
SageNET Manual
SageNET-3 (SNMP) Manual
WEBCSU-3 Datasheet
WEBCSU-3 Manual
Battery Monitor Datasheet
Battery Monitor Manual
Sageon Site Monitor Datasheet
Sageon Site Monitor Application Note

Product Information
Sageon III are 600 amp and 1200 amp Front Access DC power systems that combine a hot-swap modular rectifier unit with load distribution and multiple battery string connection.
The Sageon III 600 and 1200 amp front access DC power systems are the largest ‘Intelligent Power’ systems in the Sageon Family. They are simple to operate, with built-in intelligence to minimize manual adjustments and measurement settings, while providing information about system health and reliability.
The Sageon® III systems are capable of delivering either 600A (28kW) or 1200A (56kW) N+1 blocks of power for -48V applications and include up to 60 distribution breakers, all in a single 7ft bay.
The basic Sageon® components of smart rectifier, controller and flexible distribution enable this system to be easily sized.
The Sageon® family of power systems products will always accommodate your changing power needs and is designed to allow you to remotely view, record and act upon all the data from a site. The Sageon® III gives you the capability of battery and site monitoring demanded in today’s market.
Three Year warranty
Features and Options
- TRUE FULL Front Access
- 600A or 1200A Capacity
- 60-Way load Distribution
- 2400W Hot-Swap Rectifiers
- Battery Testing
- Battery Monitoring
- Remote Monitoring & Control
- Programmable Battery Recharge
- Field Replaceable Controller
- LCD Display/Touchpad
SPECIFICATIONS
|
|
---|---|
INPUT | |
Voltage Range | AC 85-300VAC (L-N. 1ph, or 3ph-Y, 3ph-delta [option]. Fully protected up to 440VAC (L-N) |
Frequency | 47-63Hz |
Inrush Current | <16A RMS per rectifier |
THD | Line Harmonics meet EN61000-3-2 |
Power Factor | >0.98 for >50% output power |
OUTPUT | |
Voltage Range | Adjustable 42.0V to 59.5V |
Current Limit | 55A per 48V rectifier module, fully adjustable |
Power Limit | 2400W per rectifier module |
Efficiency | >90% at 100% output power for 48VDC systems |
Regulation | ±1% or better over line, load and temperature |
Noise | .1% pk-pk max. |
Line Regulation | <1mV RMS Psophometrically weighted <32dBrnC Voiceband <10mV RMS and <100mV peak-to-peak (10kHz-100MHz) |
PROTECTION | |
Short Circuit | Can sustain short circuit at output terminals indefinitely |
Reverse Battery Polarity | Internal fuse at output of RECTIFIER, integral battery circuit breakers and detection/disconnection circuitry |
High Voltage Shutdown | Rectifier shuts down if output exceeds programmed overvoltage limit |
Electrostatic Discharge (ESD) | IEC 61000-4-2 (Level 4: Air 15kV, Contact 8kV) |
AC Surge | IEC 61000-4-4 (EFT), Level 4 IEC 61000-4-5 (Impulse), Level X: 6kV/3kA IEC 61000-4-12 (Ringwave), Level X: 6kV/500A |
RF Immunity | IEC 61000-4-3 (Radiated), Level 4 IEC 61000-4-6 (Conducted), Level 3 |
RF Emissions | CISPR 22 Class B, (Conducted & Radiated) |
ENVIRONMENTAL | |
Operating Temp. Range | -40°C to +55°C (Full Load) |
Derating Operation | 50% power at +70°C |
Storage Temp. Range | -40°C to +70°C |
Humidity | 0 to 100% relative humidity, condensing |
Acoustic Noise | <45db (80% load, 25°C); <55db (100% load, 50°C) (A weighted) |
PHYSICAL SPECIFICATIONS | |
Dimensions, inches (mm) | 84 (2134) H x 24 (610) W x 24 (610) D |
Weight | 575lb (261kg) |
COMPLIANCE | |
EMC | ETSI EN 300 386 V1.3.2 (2002-12) |
Safety | IEC 60950, UL/CSA 60950 |
Environmental | ETSI EN 300 019 |
SYSTEM LAYOUT |
---|
![]() |