Product Information

Sageon II PMD is a 200 amp, 400 amp and 600 amp Front Access DC power system that combines hot-swap modular rectifier unit with a 20 way or 40 way distribution.

Features of the Sageon II PMD is a -48VDC 200 amp, 400 amp and 600 amp Front Access DC power system include a high density with rectifiers up to 16.1 watts per cubic inch, an optional  remote access providing monitor and control of the complete power system, automatic or on-demand battery testing, continuous, individual battery cell level monitoring, providing 24 hour automated out-of-tolerance alarming and detailed identification by cell number, programmable battery recharge current and a wide input voltage range from 85 to 285 volts AC.

Sageon II PMD is a 200 amp, 400 amp and 600 amp Front Access DC power systems are shipped ready to mount in a mid-mount configuration for installation into standard 19 or 23 inch relay racks. Flush mount options also are available.

THREE YEAR WARRANTY

Features and Options
  • TRUE FULL Front Access
  • 200A, 400A or 600A Capacity
  • 20-Way or 40-Way Breaker Distribution
  • 2400W Hot-Swap Rectifiers
  • Battery Testing
  • Battery Monitoring
  • Remote Monitoring & Control
  • Programmable Battery Recharge
  • Field Replaceable Controller
  • LCD Display/Touchpad
SPECIFICATIONS
 
INPUT
Voltage Range AC 85-300VAC (L-N. 1ph, or 3ph-Y, 3ph-delta [option].
Fully protected up to 440VAC (L-N)
Frequency 47-63Hz
Inrush Current <16A RMS per rectifier
THDLine Harmonics meet EN61000-3-2
Power Factor>0.98 for >50% output power
 
OUTPUT
Voltage Range Adjustable 42.0V to 59.5V
Current Limit 55A per 48V rectifier module, fully adjustable
Power Limit

2400W per rectifier module

Efficiency>90% at 100% output power for 48VDC systems
Regulation ±1% or better over line, load and temperature
Noise .1% pk-pk max.
Line Regulation <1mV RMS Psophometrically weighted
<32dBrnC Voiceband
<10mV RMS and <100mV peak-to-peak (10kHz-100MHz)
 
PROTECTION
Short Circuit Can sustain short circuit at output terminals indefinitely
Reverse Battery Polarity Internal fuse at output of RECTIFIER, integral battery circuit breakers and detection/disconnection circuitry
High Voltage Shutdown Rectifier shuts down if output exceeds programmed overvoltage limit
Electrostatic Discharge (ESD) IEC 61000-4-2 (Level 4: Air 15kV, Contact 8kV)
AC Surge IEC 61000-4-4 (EFT), Level 4
IEC 61000-4-5 (Impulse), Level X: 6kV/3kA
IEC 61000-4-12 (Ringwave), Level X: 6kV/500A
RF Immunity IEC 61000-4-3 (Radiated), Level 4
IEC 61000-4-6 (Conducted), Level 3
RF Emissions CISPR 22 Class B, (Conducted & Radiated)
 
ENVIRONMENTAL
Operating Temp. Range -40°C to +55°C (Full Load)
Derating Operation50% power at +70°C
Storage Temp. Range -40°C to +70°C
Humidity 0 to 100% relative humidity, condensing
Acoustic Noise <60dB (A weighting)
 
PHYSICAL SPECIFICATIONS
Dimensions, inches (mm) 15.75-33.25 (400-845) H x 19.0 (483) W x 14.0 (355) D - see configurations table
Weight 61-126lb (28-57kg) - see configurations table
 
COMPLIANCE
EMCETSI EN 300 386 V1.3.2 (2002-12)
Safety IEC 60950, UL/CSA 60950
EnvironmentalETSI EN 300 019
STANDARD SYSTEM CONFIGURATIONS (see datasheet for full details)
Type Output
Current
Example Height Weight
List 24 200A 9RU 61lb | 28kg
List 25 200A 11RU 81lb | 37kg
List 26 200A 13RU 81lb | 37kg
List 27 200A 15RU 101lb | 46kg
List 44 400A 11RU 81lb | 37kg
List 45 400A 13RU 101lb | 46kg
List 46 400A 15RU 101lb | 46kg
List 47 400A 17RU 121lb | 55kg
List 64 600A 13RU 86lb | 39kg
List 65 600A 15RU 106lb | 48kg
List 66 600A 17RU 106lb | 48kg

List 67

600A 19RU 126lb | 57kg